Search

 

Apple iPhone 16 Pro Max FCC SAR Test Explained – Understanding the Report Summary

Apple iPhone 16 Pro Max SAR Level Summary:

The cellular transmission SAR values for the Apple iPhone 16 Pro Max (FCC ID BCG-E8684A) are 1.01 W/kg (watts per kilogram) at the head and 1.15 W/kg when worn on the body. The hotspot/Airplay SAR level is 1.15 W/kg. The simultaneous transmission SAR values for iPhone 16 Pro Max (cellular plus Wi-Fi) is 1.41 W/kg at the head1.55 W/kg when worn on the body, and 1.55 W/kg when used as a hotspot simultaneously with other transmitters active.

iPhone 16 Pro Max

Head SAR (Cellular Only)
Radiation Levels Head Body Hot Spot
Cellular Only 1.01 W/kg 1.15 W/kg 1.15 W/kg
Wi-Fi + Cellular 1.41 W/kg 1.55 W/kg 1.55 W/kg

Apple iPhone 16 Pro Max SAR Levels and Health Risks:

As we analyze the SAR levels for the new Apple iPhone 16 Pro Max (Model A3084), it’s crucial to delve deeper into the broader discussion of radiofrequency radiation (RFR) health risks and why consumers should be paying close attention to the latest data. While the FCC’s SAR guidelines ensure that cell phones comply with the thermal limits of radiation exposure, they fail to address non-thermal biological effects that could have long-term implications on human health.

Understanding SAR: What the Numbers Mean

The Specific Absorption Rate (SAR) measures the amount of RF energy absorbed by the body from wireless devices like smartphones. SAR limits for the general population are set at 1.6 W/kg for 1g of tissue, designed to prevent excessive heating of tissue. However, these limits were established over 25 years ago and do not reflect the non-thermal biological effects that scientists are increasingly finding to be of concern.

Apple iPhone 16 Pro Max SAR Breakdown

iPhone 16 Pro Max

Apple iPhone 16 Pro Max

Apple iPhone 16 Pro Max

Apple iPhone 16 Pro Max
Screen Size: 6.9 inches
163 x 77.6 x 8.3 mm (6.42 x 3.06 x 0.33 in)

Original price was: $69.99.Current price is: $45.47.

Apple iPhone 16 Pro Max
Head SAR (Cellular Only)
1.01 W/kg
Body SAR (Cellular Only)
1.15 W/kg
Hot Spot SAR (Cellular Only)
1.15 W/kg
Head SAR (Wi-Fi + Cellular)
1.41 W/kg
Body SAR (Wi-Fi + Cellular)
1.55 W/kg
Hot Spot SAR (Wi-Fi + Cellular)
1.55 W/kg

These rankings should serve as a starting point for consumers looking to minimize RF radiation exposure. It’s important to remember that SAR values are only one factor to consider, and other aspects such as design, antenna placement, and network coverage can also impact a phone’s overall radiation emission.

Different SAR Test Positions

When measuring a phone’s SAR values, various test positions are considered to account for the different ways in which a phone is used. The Federal Communications Commission (FCC) assesses several test positions to ensure that phones comply with the SAR limits for safe radiation exposure. These test positions include:

Cellular Values:

Simultaneous Values:

  1. Head SAR: This value is determined when the phone is held against the ear during a call. It measures the amount of radiation absorbed by the head, which is crucial since the brain is the most sensitive organ to RF radiation.
  2. Body SAR: The body SAR value measures the amount of radiation absorbed when the phone is carried close to the body, such as in a pocket or a bag. This value is important because many people keep their phones in close proximity to their bodies throughout the day.
  3. FCC Simultaneous Values: These values consider the combined effects of multiple radiofrequency transmitters (such as cellular, Wi-Fi, and Bluetooth) operating at the same time. The values are further divided into: a. Simultaneous Head SAR: Measures the radiation absorbed by the head when multiple transmitters are active. b. Simultaneous Body SAR: Measures the radiation absorbed by the body when multiple transmitters are active.
  4. Hotspot SAR: This value represents the localized absorption of RF energy when using a phone as a Wi-Fi hotspot or tethering it to another device. The hotspot SAR value is important for users who often share their phone’s internet connection with other devices.
  5. Hands SAR: Although not as widely reported as the other test positions, hands SAR measures the radiation absorbed by the user’s hands while using the phone. Since hands are in constant contact with the phone, it’s essential to consider the potential risks of prolonged exposure.

Let’s break down the SAR test results for the iPhone 16 Pro Max (FCC ID: BCG-E8684A), based on the most recent report.

Test Scenario SAR Value (W/kg)
Head (single TX) 1.014
Body-worn (Dist. = 5mm) 1.149
Hotspot (Dist. = 5mm) 1.149
Extremities (Dist. = 0mm) 1.939

Simultaneous Transmission SAR Values (multiple wireless connections active):

Condition SAR Value (W/kg)
Head (Simultaneous TX) 1.410
Body-worn (Simultaneous TX) 1.545
Hotspot (Simultaneous TX) 1.545
Extremities (Simultaneous TX) 2.079

The highest reported power density (PD) for this device was 0.694 mW/cm², which is below the general population limit of 1.0 mW/cm² for uncontrolled exposure.

While these values comply with the current FCC standards, it’s critical to ask: Are these guidelines sufficient to protect public health in today’s rapidly evolving wireless environment?

The FCC’s Lawsuit Loss and Outdated 1996 Guidelines

In 2020, the Federal Communications Commission (FCC) lost a significant lawsuit brought forward by the Environmental Health Trust (EHT) and Children’s Health Defense. The plaintiffs challenged the FCC’s decision to maintain the RF radiation exposure limits that were set in 1996, despite substantial advancements in wireless technology and the widespread use of mobile devices.

The Court’s Decision

The U.S. Court of Appeals for the District of Columbia Circuit ruled in favor of the plaintiffs, finding that the FCC had failed to provide a reasoned explanation for maintaining its 1996 guidelines. The court criticized the FCC for not addressing evidence regarding the potential health risks posed by long-term exposure to RF radiation, especially for vulnerable groups like children.

This ruling highlights the critical need for a thorough review of current RF radiation exposure limits, which were developed more than two decades ago when mobile technology was far less prevalent. The FCC’s guidelines have remained unchanged, despite an explosion in the use of mobile devices and the emergence of scientific evidence suggesting possible health risks from prolonged exposure to RF radiation.


Factors Contributing to Low Radiation Emission in Cell Phones

As concerns about the potential health impacts of RF radiation continue to grow, it is essential for consumers to understand the factors that can influence the radiation levels emitted by their cell phones.

1. Design and Technology

The design and technology of a mobile phone can significantly affect its radiation emissions. Manufacturers continually strive to reduce RF radiation through innovative designs. Advances in antenna design, power management, and materials used in phone construction can all contribute to lowering radiation levels. For instance, improved antenna designs can focus energy more efficiently, reducing unnecessary radiation.

2. Antenna Placement and Performance

The location and performance of a cell phone’s antenna play a crucial role in the amount of RF radiation emitted. Antennas positioned farther from the user’s head or body can help minimize exposure. Additionally, some phones now feature multiple antennas that distribute signal emission more effectively, reducing the radiation emitted during use.

3. Signal Strength and Network Coverage

Signal strength is another key factor influencing a phone’s radiation output. When a cell phone has a weak signal, it must work harder to maintain a connection to a tower, which increases RF radiation emissions. Phones that can efficiently operate in areas with weak signals without significantly increasing radiation output are preferable for minimizing exposure.


The Antenna Relocation Dilemma: Health Risks and Trade-offs

Relocating a phone’s antenna to minimize radiation exposure to the head can reduce certain health risks but might introduce other concerns. Some research suggests that this approach could contribute to a rise in thyroid cancer cases. For example, studies conducted in the Nordic countries indicate a potential link between increased thyroid cancer rates and mobile phone use.

Additionally, research on non-ionizing radiation has raised concerns about its effects on the thyroid gland, including potential changes in hormone levels and the development of histopathological changes. More research is needed to definitively establish this connection, but it serves as a reminder of the potential trade-offs involved in altering phone design for safety reasons.


The Problem with Relying Solely on SAR Values

The Specific Absorption Rate (SAR) is the primary metric used to measure cell phone radiation, but it has significant limitations when it comes to providing a complete picture of a phone’s radiation emissions.

Incomplete Radiation Emission Picture

A single SAR value reflects the maximum amount of RF radiation absorbed by the body under specific conditions (e.g., holding the phone to your head). However, this does not provide a comprehensive understanding of a phone’s overall radiation emission profile. For example, the SAR value measured when holding a phone to the head may be low, but the radiation emitted when the phone is carried in a pocket could be higher. This creates a false sense of security for users who assume that a low SAR value means low overall radiation emissions.

Examples of SAR Discrepancies

Some phones report low head SAR values but exhibit high body SAR values due to the phone’s design or antenna placement. This discrepancy can lead to situations where users believe they are minimizing their exposure based on the head SAR value, when in fact they may be exposed to higher radiation levels in other scenarios, such as when the phone is kept close to the body.

Potential Risks of Using One SAR Value for Comparison

Relying solely on one SAR value for comparison purposes can lead to an incomplete and possibly misleading understanding of the risks associated with a particular phone. Users should consider multiple SAR values and other factors, such as design, antenna placement, and signal strength, to get a more accurate understanding of potential exposure levels.


SAR Values and the Focus on Thermal Effects

The current SAR guidelines focus on thermal effects, measuring the rate at which the body absorbs RF energy and the resulting tissue heating. However, there is growing concern that the non-thermal effects of RF radiation may also pose health risks.

Non-Thermal Effects of RF Radiation

Emerging research suggests that RF radiation may have biological effects that are not directly related to tissue heating. These non-thermal effects include changes in cell membrane permeability, oxidative stress, potential DNA damage, and calcium efflux. While the evidence for these effects remains inconclusive, they represent a significant gap in the current SAR-based guidelines, which do not account for non-thermal risks.

By focusing exclusively on thermal effects, the SAR standard may not fully protect users from potential long-term health risks. Consumers should be aware of both thermal and non-thermal effects when assessing the safety of mobile devices.


The Call for Updated Guidelines

The 2020 court ruling against the FCC underscores the urgent need for an overhaul of the RF radiation exposure guidelines. The 1996 guidelines are clearly outdated and fail to reflect the current scientific understanding of RF radiation and its potential health effects.

What Needs to Change?

  1. Consideration of Non-Thermal Effects: Any updated guidelines must take into account the non-thermal biological effects of RF radiation, which are increasingly being studied and linked to various health risks.
  2. Adjusting for Vulnerable Populations: The new guidelines should also account for the increased sensitivity of children, pregnant women, and other vulnerable populations who may be at higher risk of harm from long-term radiation exposure.
  3. Incorporating Advancements in Technology: The rapid evolution of mobile technology, including the introduction of 5G networks, requires a fresh look at how RF radiation emissions are regulated. New technological developments should be leveraged to create safer, lower-emission devices.

The FCC’s outdated 1996 guidelines for RF radiation exposure are no longer adequate in the face of modern wireless technology and mounting scientific evidence of potential health risks. The 2020 lawsuit brought by the Environmental Health Trust and Children’s Health Defense should serve as a wake-up call for both the FCC and consumers. While the SAR standard provides some protection, it focuses primarily on thermal effects and overlooks the possible non-thermal risks posed by long-term exposure to cell phone radiation.

Consumers should stay informed, consider multiple factors when purchasing a cell phone, and remain vigilant about the latest research on RF radiation. Ultimately, the development of updated FCC guidelines that reflect the current state of technology and scientific knowledge is essential for protecting public health in the wireless age.

A Growing Body of Scientific Evidence

In the past two decades, numerous studies have emerged that point to the non-thermal biological effects of RF radiation. These effects occur at levels far below the thermal limits and include:

  • DNA damage
  • Oxidative stress
  • Neurological effects
  • Increased cancer risk

The National Toxicology Program (NTP) and Ramazzini Institute (RI) studies are two of the most pivotal in demonstrating that RF radiation can lead to cancer in lab animals. Both studies found increased incidences of gliomas (brain tumors) and schwannomas (heart tumors) in rats exposed to RF radiation, even at levels lower than current FCC guidelines.

1. The NTP Study

The NTP study remains the largest and most comprehensive study of its kind, investigating the effects of cell phone radiation on health. The results were groundbreaking, showing clear evidence of cancer-causing activity in animals exposed to RF radiation. Male rats developed:

  • Glioblastomas (a deadly brain cancer)
  • Schwannomas in the heart

Despite these alarming findings, regulatory agencies like the FCC have failed to update their safety guidelines to reflect this new understanding.

2. The Ramazzini Institute Study

The Ramazzini Institute in Italy followed the NTP study but used exposure levels comparable to those from cell towers, rather than cell phones. Their results were strikingly similar, reinforcing the NTP’s findings:

  • Schwannomas were once again observed in the heart
  • Increased incidences of malignant tumors in exposed animals

The Ramazzini study proved that even low-level exposure to RF radiation can lead to significant health risks, raising further concerns about the adequacy of current safety standards.

Why the Public is Unaware: Regulatory Capture and the Suppression of Science

The general public remains largely unaware of the health risks associated with RF radiation, despite overwhelming scientific evidence. This ignorance is not due to a lack of research but rather a deliberate effort by regulatory bodies and industry to downplay the risks.

1. Regulatory Capture

Regulatory capture occurs when the industries that regulators are meant to oversee exert undue influence on the policies and guidelines that govern them. The FCC, for example, has been heavily influenced by the telecommunications industry, which has a vested interest in keeping the focus on thermal effects while ignoring non-thermal biological risks.

The FCC’s guidelines, established in 1996, focus solely on preventing the heating of tissues from RF radiation. They do not account for the biological effects that occur at much lower exposure levels, such as DNA damage and oxidative stress, which are critical precursors to cancer development.

2. Suppression of Science

The wireless industry has a long history of funding studies designed to minimize the perceived risks of RF radiation. Studies that show negative health effects are often dismissed, and scientists who raise concerns are marginalized. A striking example of this suppression is the Biden-Harris administration’s decision to halt NTP’s research despite its clear evidence linking RF radiation to cancer.

This suppression of scientific findings has delayed the public acknowledgment of RF radiation risks, allowing the industry to continue its unchecked expansion without addressing the potential long-term consequences for human health.

Human Cancer Morphology and the Latest Breakthrough Study

In January 2024, researchers published a groundbreaking study that sought to bridge the gap between animal and human cancer research. Utilizing tissue samples from the Ramazzini Institute’s animal studies, scientists conducted genetic profiling on the tumors that developed in rats exposed to RF radiation. The results were nothing short of revelatory.

Similarities to Human Gliomas

The study found that the tumors developed in rats shared morphological similarities with low-grade human gliomas. This finding is crucial because it addresses a common criticism of animal studies: that the results may not be applicable to humans. The genetic similarities between the tumors in rats and those found in humans suggest that the cancers induced by RF radiation in rats could indeed be mirrored in human populations.

Genetic Profiling: A Key Insight

The genetic analysis revealed that while the rat tumors did not exhibit certain common human mutations, such as IDH1 or IDH2, they did share other mutations implicated in human cancer development. These similarities provide strong evidence that the findings from animal studies are directly relevant to understanding the cancer risks posed by RF radiation in humans.

This study reinforces the need to reclassify RF radiation risks and update public safety standards to reflect the latest scientific understanding.

The Urgency of Reclassifying RF Radiation

The misclassification of RF radiation as purely a thermal hazard has stifled progress in public health protection. It has also hindered the development of medical treatments that could harness the non-thermal effects of RF radiation for therapeutic purposes.

1. Missed Medical Advancements

Emerging research suggests that RF-EMF (radiofrequency electromagnetic fields) could be used to target cancer cells and promote healing through non-thermal mechanisms. For example, the FDA-approved TheraBionic treatment uses RF radiation to treat inoperable liver cancer, relying on non-thermal biological interactions to damage cancer cells while sparing healthy tissue.

2. DARPA’s RadioBio Initiative

The RadioBio initiative, led by DARPA, seeks to understand how electromagnetic fields are used by biological organisms for communication and healing. This research could revolutionize both medicine and telecommunications, but it remains underfunded and underexplored due to the suppression of scientific evidence about the non-thermal effects of RF radiation.

What Can You Do?

The release of the Apple iPhone 16 Pro Max and its SAR levels serves as a reminder that we are surrounded by wireless technology that may be affecting our health in ways we don’t yet fully understand. The SAR levels comply with outdated guidelines that focus only on thermal effects, ignoring the growing body of evidence that points to non-thermal biological risks.

Consumers need to take steps to protect themselves:

  1. Use radiation protection products, like RF Safe cases, to reduce direct exposure to your phone.
  2. Limit your cell phone use, especially in close contact with your body.
  3. Use speaker mode or air-tube headsets to minimize RF exposure to your head.
  4. Advocate for updated safety standards that address both thermal and non-thermal effects of RF radiation.

The time to act is now. Reclassifying RF radiation risks and updating safety standards are not just necessary—they are urgent. The health of future generations depends on addressing this issue before more harm is done.

 

What is the SAR value for the Apple iPhone 16 Pro Max?

The SAR value for the Apple iPhone 16 Pro Max (FCC ID BCG-E8684A) is 1.01 W/kg at the head and 1.15 W/kg when worn on the body. These values reflect the amount of RF energy absorbed by the body during regular phone use.


Are the SAR levels of the iPhone 16 Pro Max within safe limits?

Yes, the SAR levels of the iPhone 16 Pro Max are within the FCC’s 1.6 W/kg safety limit for the general population. However, growing concerns exist that these guidelines, set in 1996, may not protect against the non-thermal biological effects of RF radiation.


What is the simultaneous transmission SAR value for the iPhone 16 Pro Max?

The simultaneous transmission SAR value for the iPhone 16 Pro Max, when both cellular and Wi-Fi connections are active, is 1.41 W/kg at the head and 1.55 W/kg when worn on the body.


How does RF radiation from the iPhone 16 Pro Max affect health?

While the iPhone 16 Pro Max complies with thermal SAR limits, studies show that non-thermal effects of RF radiation—like DNA damage, oxidative stress, and neurological issues—may pose health risks, even at lower levels of exposure.


What are the highest SAR values for the iPhone 16 Pro Max?

The highest SAR values for the iPhone 16 Pro Max include 1.01 W/kg at the head, 1.15 W/kg on the body, and 1.94 W/kg for extremities under various testing scenarios.


Should I be concerned about the RF exposure from the iPhone 16 Pro Max?

Yes, concerns exist that non-thermal biological effects of RF exposure, such as cellular damage and increased cancer risks, are not adequately addressed by the current FCC guidelines. It’s recommended to take precautionary steps to reduce exposure.


Why are SAR guidelines for phones like the iPhone 16 Pro Max outdated?

The FCC SAR guidelines, established over 25 years ago, focus only on thermal effects of RF radiation, ignoring non-thermal biological effects like oxidative stress and DNA damage, which research has shown to occur at much lower exposure levels.


How can I reduce RF exposure from the iPhone 16 Pro Max?

To reduce RF exposure, use speakerphone, air-tube headsets, or RF-safe accessories. Additionally, keep the phone away from your body during long calls and turn off wireless functions like Wi-Fi and Bluetooth when not in use.


Is the iPhone 16 Pro Max safe for children to use?

Children are more vulnerable to RF radiation due to their developing brains and longer exposure time throughout life. While the iPhone 16 Pro Max meets current SAR limits, reducing children’s exposure is advisable to mitigate long-term risks.


What do studies say about the health risks of RF radiation from phones like the iPhone 16 Pro Max?

Studies like the National Toxicology Program (NTP) and the Ramazzini Institute have found links between RF radiation and brain tumors and heart tumors in lab animals, raising concerns about the adequacy of current safety standards for human health.

 

The highest reported values for each category based on the FCC report:

Highest Reported SAR (W/kg) Values:

  • Head (single TX):
    • 1.014 W/kg under the DTS condition.
  • Body-worn (Dist. = 5 mm):
    • 1.149 W/kg under the NII condition.
  • Hotspot (Dist. = 5 mm):
    • 1.149 W/kg under the NII condition.
  • Extremities (Dist. = 0 mm):
    • 1.939 W/kg under the TNE condition.

Simultaneous Transmission (TX) SAR Values:

  • Head (Simultaneous TX):
    • 1.410 W/kg under multiple conditions (PCE, DTS, NII, 6CD).
  • Body-worn (Simultaneous TX):
    • 1.545 W/kg under multiple conditions (DTS, NII, 6CD, DSS).
  • Hotspot (Simultaneous TX):
    • 1.545 W/kg under multiple conditions (DTS, NII, 6CD, DSS).
  • Extremities (Simultaneous TX):
    • 2.079 W/kg under the TNE and 6CD conditions.

These are the highest reported SAR values from the table for each condition and category.

 

Applicant Name & FCC ID:

  • Applicant Name: This indicates the entity applying for the FCC certification, which is Apple Inc. in this case.
  • FCC ID: This is a unique identifier assigned to the device by the FCC. Here, it is BCG-E8684A, specific to the A3084 model.

Model Name:

  • The model name is A3084, corresponding to the device under test, which in this case is the Apple iPhone 16 Pro Max (USA).

Applicable Standards:

  • The test procedures follow RF exposure KDB procedures and IEEE Std 1528-2013, which are the testing standards and guidelines set by the FCC for Specific Absorption Rate (SAR) testing. KDB refers to the FCC’s Knowledge Database, and IEEE 1528 is a standard for SAR evaluation.

SAR Limits (W/kg):

  • Peak Spatial-Average (1g of tissue): This refers to the SAR limit for the general population, set at 1.6 W/kg for 1 gram of tissue. This value measures how much RF energy is absorbed by a certain amount of body tissue (1g).
  • Extremities (10g of tissue): This SAR limit applies to parts of the body like hands, wrists, and ankles, where the SAR threshold is typically higher (set at 4 W/kg), as these areas are less sensitive compared to the head and torso.

Exposure Categories:

  • General population / Uncontrolled exposure: This refers to exposure limits for the public, which must be kept under the stated SAR thresholds to avoid health risks from prolonged exposure to RF energy.

RF Exposure Conditions:

These conditions simulate how the phone might be used under different scenarios. Here’s what each term means:

  • TNE: Test Network Environment, simulates network traffic under different conditions.
  • PCE: Peak Controlled Exposure, measures the highest possible exposure level.
  • CBE: Controlled Body Exposure, represents typical body contact scenarios.
  • DTS: Device Test Scenario, tests SAR in regular device use.
  • NII: Non-Intentional Interference, evaluates unintended interference between networks.
  • 6CD: Six-Class Domain, a less common testing category used in niche cases.
  • DSS: Dynamic Spectrum Sharing, reflects RF exposure in network-sharing situations.
  • DXX: Dynamic Excess Exposure, measures unusually high exposure in specific test cases.

SAR Values (W/kg):

  • SAR values are broken down into different categories:
    • Head: SAR measured when the device is held against the head.
    • Body-worn (Dist. = 5 mm): SAR when the device is worn close to the body (e.g., in a pocket or belt).
    • Hotspot (Dist. = 5 mm): Hotspot testing occurs when the phone is held in a manner where the highest SAR occurs in localized spots.
    • Extremities (Dist. = 0 mm): When the device is held directly against extremities (e.g., hands or wrists).

These SAR values represent how much RF energy is absorbed in each test scenario, and the measurements should ideally be below the SAR limit for safe use.

Simultaneous Transmission (TX):

This section shows the SAR values when multiple wireless connections are being used at the same time (e.g., Wi-Fi and cellular). Simultaneous TX reflects combined exposures from all active wireless technologies. These are split into:

  • Head: SAR measured when the phone is used near the head.
  • Body-worn: Measured when the device is close to the body.
  • Hotspot: Measured during the device’s hotspot usage.
  • Extremities: Measured when the phone is in contact with hands, feet, etc.

Radiofrequency (RF) Radiation Exposure:

  • Uncontrolled: Limits for general public exposure, where prolonged contact must be kept below 1.0 mW/cm² averaged over 30 minutes.
  • Occupational/Controlled: Higher exposure limits allowed for professionals who are aware of the risks, set at 5.0 mW/cm² over a 6-minute average.

PD Result:

  • PD Result: This measures the power density (RF exposure) result. In this case, 0.694 mW/cm² is noted, which is below the uncontrolled exposure limit of 1.0 mW/cm².

Date Tested & Test Results:

  • Date Tested: Indicates the date range during which the device underwent testing (6/24/2024 to 7/30/2024).
  • Test Results: The pass label indicates that the device complies with the FCC’s RF safety guidelines.

Each section of the report provides critical information regarding how much radiofrequency radiation (RF) is absorbed by the body in various scenarios, from talking on the phone to wearing it close to your body. Understanding SAR values is essential to ensure that your device is within safe limits for RF exposure, helping protect you from excessive radiation.

 

 

Free Worldwide shipping

On all orders above $100

Easy 30 days returns

30 days money back guarantee

Replacement Warranty

Best replacement warranty in the business

100% Secure Checkout

AMX / MasterCard / Visa